Aggregates find a wide range of applications as they are used in many industries including construction. We always ensure the best quality products to withstand the heavy duty use involved in the aggregate industry. Irrespective of whether the application is for low tonnage or very high tonnage, whether the application is for heavy rock or gravel or sand, we can ensure that your needs are met.

 

Belt Name Ts Abr Mm3 Max Temp Elong % Characteristics Suitability Material Eqvl grade Standards Applicable
LTHA Lower Tensile
Higher Abrasion
17 200 80 400 Lower Tensile Strength, lesser Cuttling,
gouge & Abrasion resistant
Powdery Material Coal, Ash, Cement etc. N-17 IS 1891
LTMA Lower Tensile Medium Abrasion 17 150 80 400 Lower Tensile Strength, Cutting, Gouge
& resistenace But Highly abrasion Resistant
Lumps and Rugged
Material etc
Coal, Alumnia, Ash, Cement etc N AS
LTSA Lower Tensile Super Abrasion 18 70 80 400 Lower Tensile Strength, Cutting, Gouge Resistance But Super abrasion Resistant Extremely Abrasive Lumps and Rugged Materials Metal & Iron Ore, Limestone, Glass Slag etc. A/ W/ SAR AS/DIN
HTMA Higher Tensile Medium Abrasion 24 150 80 450 High on Tensile Strength cutting & Gouge resistance Moderate Abrasion Resistant Sharp Large Lumps & Rugged Material High Impact Coal, Copper ore, etc. M-24 IS 1891
L th Low Temperature 13 200 S: 100 M: 125 350 Lower Heat, Abrasion, Cut & tear Resistant Moderately Heated Material Fertilisers, Pellets & Chemicals Heated HR T 1 IS 1891
H th High Temperature 13 180 S: 125 M: 150 350 Higher Heat, Cut, Abrasion & tear Resistant High Temperature Material Hot cement, Sintered Ore, Chemicals & Ore, Fertilisers HR T 2 IS 1891
Firepro 17 200 80 350 Fire retardant for Surface application Open Cast Mines Power Stations etc. Coal & Matis, with Fire Hazards FR IS 1891/V CAN CSA/C
Firepro + 17 160 80 400 Fire retardant for Surface application Faster extinguishing & low abrasion Resistant Open Cast Mines Power Stations etc. Coal & Other Matis, with Fire Hazards FR ISO 340 ISO